Initializing...
Preview
CS2-A-3000-100-107-CJ

CS2-A-3000-100-107-CJ

CS2 with Cooling Jacket (CJ ) for use with a liquid cooler unit. Delay capable.
Every time a CS2 controllable gas spring is stroked, energy is transferred from the press to the spring. The amount of energy transferred is a function of the spring force multiplied by its stroke length.
For applications where a larger number of CS2 springs operate at higher production rates, liquid cooler units are recommended. For applications where liquid cooling is required each CS2 gas spring is fitted with a cooling jacket.

Diagram / specifications section

Preview
LMinimum Length (in)9.53
SStroke Length (in)4.21
YTotal Length (in)13.74

Item specifications

  • End Force At Full Stroke (LBF)9400
  • Force Increase By Temperature Percent Per (°F)0.17
  • Gas Volume (CuF)0.02966432
  • Initial Force at max. pressure (lbf) 6744
  • Max Charging Pressure (Psi)2175
  • Max Piston Rod Velocity (FtMin)157.48
  • Max. Operating Temperature (F)176
  • Min Charging Pressure (PSI)362
  • Min. Operating Temperature (F)32
  • Recommended Max Strokes Per MinuteSee separate info.
  • Weight (lb)30.514

Accessories

Similar items

CS2-A-3000-100-107-NC
CS2-A-3000-100-107-NC
CS2-A-3000-100-107-NC
CS2-3000-107-CJ
CS2-3000-107-CJ
CS2-3000-107-CJ
CS2-3000-107-NC
CS2-3000-107-NC
CS2-3000-107-NC
CS2-3000-107
CS2-3000-107
CS2-3000-107
CS2-A-3000-100-107
CS2-A-3000-100-107
CS2-A-3000-100-107